- Other type designation: Ferralux
HIGHLIGHTS CENTRAL AIR HANDLING UNITS
- compact design for installation in false ceilings, raised floors or for manifold installation
- convenient interconnection of outlets to form ventilation groups
- Ventilation control units can be connected in series for centralized functions (cascadable)
- Ventilation pushbutton inputs with OPEN-STOP-CLOSE function, controllable with up to 3 priorities for higher-level commands
- Input for potential-free wind and rain signals to prevent weather damage
- suitable for integration into data bus systems (LON, KNX) for controlled natural ventilation
- Programming of special functions via PC software
- Control relay for installation in flush-mounted device boxes behind the ventilation pushbuttons for individual or group control of 24 V D and 230 V AC drives
MOUNTING VENTILATION CONTROL UNITS
You can use AUMÜLLER ventilation control units and power supply units in systems for natural ventilation via windows operated by electric motors. Depending on the version, control is either via the 230V AC primary side or via the 24V DC secondary voltage. For some control relays you need an external power supply. A selection of power supply units is available for this purpose.
The flat, space-saving housings of the ventilation control units can be installed in suspended ceilings or even in raised floors. You do not need to worry much about the assignment of the window drives or the drive outputs in ventilation groups. You can change them at any time by interconnecting the inputs.
The switching relays for 24V DC and 230V AC drives can be installed both in surface-mounted and flush-mounted switch boxes. These versions are also available for installation in distribution boxes.
The switching power supplies are partly available in their own housings, partly for installation in distribution boxes.
TECHNICAL DATA (rated values)
- Operating voltage: 230 V AC (195 - 253 V AC, 50/60 Hz)
- Power consumption: 60 W
- Output voltage: 24 V DC (20 - 28 V DC / 2 Vpp)
- Output current: 2.5 A
- Inputs: 1 ventilation pushbutton line with 3 priorities
- Outputs: 1x drive line; 1x 24 V DC / 500 mA (e.g. for rain sensor)
- Displays: Operation, output voltage in OPEN/CLOSED direction
- Slots: BUS modules (LON, KNX)
- Connections: S12 drives for communication with BUS modules
- Housing: aP, plastic (ABS)
- Dimensions (WxHxD): 180 x 130 x 60 mm
- Connection terminals: Screw terminals 2.5 mm² (rigid)
- Protection class: IP54
FEATURE/EQUIPMENT
- DIP-switch for configuration of the input with lowest priority in latching or deadman mode
- Inputs of several LZ1 and/or LZ6 can be connected in parallel
- When using a BUS module, drives with intelligent load disconnection electronics S12 can be controlled via BUS protocol for controlled natural ventilation
Technical advice
+49 9282 48731-15
technik@bsc-technology.de
Fast delivery
... of goods in stock. Orders placed before 14:00 are usually shipped the same day.
Questions about the article
Voltage : | 230V AC |
Output voltage : | 24 V DC |
Scope of delivery: | Ventilation center without BI-K - KNX interface module |
Dimensions: | 180 x 130 x 60 mm |
Housing: | aP, plastic (ABS) |
Output voltage: | 2,5A |
Scope of delivery
Ventilation center without BI-K - KNX interface module