scope of application
- 1 RWA / ventilation area
- Control of window drives up to 4.8A
- with microcontroller technology
- Smoke extraction of small and medium-sized construction objects
- expandable with additional plug-in modules
- Incl. 2 emergency power batteries type WSA 003
RWA compact control panel for controlling 24V DC drives for the smoke extraction function combined with daily ventilation. The RWA center is suitable for smaller building objects, such as Staircase smoke extraction systems, small sports halls, restaurants etc.
The RWA compact control panel is supplied with plastic housing and can be used for flush / surface mounting (frame for surface mounting included).
WSC 204KP:
The RWA compact control center opens the window drives at RWA. The control panel is equipped with a release button and comfort control in the door. This eliminates the need for external keypads, ventilation buttons and associated cabling for easier and faster installation. The ventilation button is used for daily ventilation operation.
extension
By cascading (linking) several controllers, even larger building objects can be realized in a decentralized system (master / slave module WSA 301 required).
Features
- certified according to EN 12101-10
- Smoke control combined with ventilation
- built-in emergency power supply for min. 72 hours by battery backup
- Line monitoring SHE button
- Line monitoring RWA detector (if used)
- Monitoring the drive supply line
- Breakage of the detector lines 1 and 2 separately visible on the LEDs
- Fault indication via diagnostic LEDs
- Fault message also programmable as RWA tripping
- SHE activation at temperature within the control panel greater than 72 ° C
connection options
- Drive with limit switch or electronic load shutdown
- Triggered by BMA via potential-free contact (BMZ module WSA 306 required)
- With comfort ventilation, signals from BMS systems can be received
- Wind / rain detector can be connected without additional module
- 15 pieces ventilation button with display or any number of buttons without display
- 10 automatic detectors type WSA 300 61 or WSA 310
- 4 RWA main control panels type WSK 320 or type WSK 321
- 15 RWA secondary control panels type WSK 330
Technical advice
+49 9282 48731-15
technik@bsc-technology.de
Fast delivery
... of goods in stock. Orders placed before 14:00 are usually shipped the same day.
Questions about the article
Voltage : | 230V AC |
Protection class : | IP 30 |
Number of SHEV buttons : | any |
Number of automatic detectors : | 10 |
Ventilation button quantity : | 15 |
Emergency operation : | > 72 St |
Ambient temperature : | -5°C - +40°C, max. 90% Relative humidity (non-condensing) |
Scope of delivery: | RWA-Kompaktzentrale mit 2 Notstromakkus 12V/3,4Ah (2 x WSA 003) |
Dimensions: | 368x353x Aufputz 97mm oder Unterputz 95mm |
Output current: | 4,8A |
SHEV groups: | 1 |
Ventilation groups: | 1 |
Scope of delivery
RWA-Kompaktzentrale mit 2 Notstromakkus 12V/3,4Ah (2 x WSA 003)