Product finder
Step by step to the right product

>> To our product consultants

Printable checklists
Send in and receive offer

>> To the checklists

HAUTAU Tandem sequence control FTA 3.1 - 24V

24 V DC
14096
300976
4015915249167

Ready to ship today, Delivery time appr. 1-3 workdays
Important info about the delivery time

€137.57 *

incl. VAT plus shipping costs

Leave your email address and stay informed about this article.

as soon as the item is back in stock
as soon as the item drops in price
as soon as the item is available as a special offer
  • Images, texts, data sheets from HAUTAU GmbH
To control several drives on one window, the use of a sequence control is necessary. In order... more

To control several drives on one window, the use of a sequence control is necessary. In order to exclude a hazard at an automatically operated window, the use of safety elements is often necessary.

Tandem sequence control FTA 3/N with housing Control of the logical switching sequence of drives and locking drives with housing. Connection options Drives and additional interlocks (with and without load disconnection) up to 2 A per channel with line monitoring. Range of application The control unit enables: - operation of max. 2 drives in tandem mode, - operation of max. 2 drives and one interlocking drive as tandem sequence control, - operation of max. 2 drives and one interlocking drive as sequence control, - operation of one drive and max. 2 interlocking drives as sequence with interlocking running in parallel. Special feature Monitoring of the interlocking circuit or 1st channel in the "Open" direction. A tear-off and a non-function is recognized as a "fault" and indicated with an LED.

Technical data

  • Operating voltage: 24 V DC
  • Max. Current per output: 2 A Min
  • Current per output: 0.1 A
  • Ambient temperature: - 20 °C to + 50 °C
  • Protection class (according to DIN 40 050) protected against dust deposits and dripping water IP 52 (in housing)
  • Max. Cable length at the outputs: 3 m
  • Time delay in tandem operation: 3 s
  • Max. Load of the fault line: 100 mA Max. line cross-section: 2.5 mm²
  • Housing plastic light gray
  • Dimension housing WxHxD: 96 x 96 x 40 mm

For further information on this article, please refer to the documents in the download area.

Technical advice

+49 9282 48731-15
technik@bsc-technology.de

Fast delivery

... of goods in stock. Orders placed before 14:00 are usually shipped the same day.

Questions about the article

to the inquiry form

Technical data more
Scope of delivery: Control
Scope of delivery & accessories more

Scope of delivery

Control

Read, write and discuss reviews... more
Customer reviews for "HAUTAU Tandem sequence control FTA 3.1 - 24V"
Write rating
Reviews will be activated after verification.

The fields marked with * are required.

Last viewed